Carrying a body through a step

A leg holds a mass up while moving it forward. A person, a walking humanoid, and a powered prosthesis each solve that, and Corpus can draw all three on the same axis without claiming they solve it the same way.

All comparisons

The axis

Bearing body load through an articulated limb while moving it through a step

The axis is a task, not a part. Each participant has to hold a mass above the ground, let the limb fold and extend as the body passes over it, and return the limb to the front for the next step. That task is what makes the three comparable, and it is the only thing being compared.

What this axis does not license: Sharing the task says nothing about mechanism, range, durability, energy use, comfort, sensation, or outcome. It does not make a prosthesis a leg, a humanoid a person, or a person a machine, and it does not rank any of them against another.

HUMAN

The limb that bears the load

Canonical human
  • The Corpus human atlas resolves the lower limb as whole structures: a femur, a skeletal system, a muscular system. There is no knee mesh and no separate muscle or ligament. The human side of a limb comparison is therefore drawn at limb resolution, not joint resolution.

Bone carries the compressive load, muscle and connective tissue hold the joint together and drive it, and the whole limb alternates between supporting the body and swinging clear of the ground.

  • Left femur
  • Skeleton
  • Muscles
Corpus draws 3 of 28 nodes in this model for this axis. That is how much of the model Corpus holds, not how complex the thing is.

HUMANOID

The articulated leg assembly

Unitree G1 with hands
  • This figure is one vendor's research platform, drawn from the robot description that vendor publishes for simulation. It shows that platform's link geometry and joint layout, not a general humanoid design, and not the actuators, materials, or ratings inside the links.

A shell segment carries the load into a chain of single-axis joints. Each joint is a discrete named component with its own drive, so the arrangement is a kinematic tree rather than a continuous structure.

  • Pelvis
  • Left Hip Pitch
  • Left Hip Roll
  • Left Hip Yaw
  • Left Knee
  • Left Ankle Pitch
  • Left Ankle Roll
Corpus draws 7 of 66 nodes in this model for this axis. That is how much of the model Corpus holds, not how complex the thing is.

TRANSHUMAN

The engineered limb below the socket

Powered lower-limb prosthesis
  • Device geometry in a Transhuman configuration is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.

A socket transfers load from the residual limb into a powered knee, a pylon, and a powered ankle. Everything below the socket is device; everything above it is the person the device is fitted to.

  • Socket
  • Residual limb interface
  • Powered knee unit
  • Pylon
  • Powered ankle unit
  • Prosthetic foot
Corpus draws 6 of 11 nodes in this model for this axis. That is how much of the model Corpus holds, not how complex the thing is.

What is actually claimed

Every pairing states its own limit.

Placing two things side by side implies they belong together. Each claim below carries what the two share and what sharing it does not carry over, and the build refuses a claim that leaves the second half out.

  1. Shared: Both hold a mass above the ground through a segmented limb, and both let that limb fold and extend so the body can pass over the supporting foot.

    Not shared: The humanoid knee is a single hinge turning on one fixed axis. A human knee rolls, slides, and rotates as it bends, and the surfaces that let it do so are held together by tissue the atlas does not resolve. Corpus draws the human side at limb resolution, so the two are alike as load paths and not as joints.

    • An analogy here says two things play a corresponding role on the stated axis. It does not say they work the same way, are built the same way, perform the same way, or can be exchanged for one another.
    • The Corpus human atlas resolves the lower limb as whole structures: a femur, a skeletal system, a muscular system. There is no knee mesh and no separate muscle or ligament. The human side of a limb comparison is therefore drawn at limb resolution, not joint resolution.
  2. Shared: After a transfemoral amputation the knee, shank, and foot are gone. The device stands in for their part of the task: it accepts load from above and provides the joint motion the step needs.

    Not shared: Standing in for a task is not restoring the limb. The device supplies no sensation, no tissue, and no growth or repair, and the person still carries the residual limb, the socket, and the fit between them. Substituting for a role is the whole of the claim.

    • An analogy here says two things play a corresponding role on the stated axis. It does not say they work the same way, are built the same way, perform the same way, or can be exchanged for one another.
    • No quantity on this axis is measured the same way in two of these domains. Nothing here supports a claim that one of them is faster, stronger, more efficient, or more capable than another.
  3. Shared: The socket is where the two meet. Load, motion, and misalignment all cross that boundary, which is why it is drawn as a component of the configuration rather than as part of either side.

    Not shared: Corpus places this boundary on a reviewed anchor that resolves to a whole atlas structure. The rendered position indicates a body region, not a socket fit, a residual limb shape, or a surgical level.

    • Device geometry in a Transhuman configuration is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.
    • None of this is clinical, surgical, rehabilitation, or engineering guidance, and it describes no individual person, patient, or device.

Joint resolution · published simulation models

How each model represents the hip, knee, and ankle

The atlas draws the human limb as whole structures, so the figures above stop at limb resolution. These four published MuJoCo models go further, and they disagree on what a joint is: the musculoskeletal model bends its knee on one coordinate and couples rolling, sliding, and patellar motion to it, while each robot knee is one hinge. Read on the left side, reviewed 2026-10-14.

Every value here is read out of a published simulation model, not measured on a person, a robot, or a device. A model's joint limit is what its authors set for simulation; a robot's torque limit in its model can differ from the manufacturer's quoted peak, and a muscle's peak isometric force is a model parameter scaled from cadaver and imaging studies. The models are not measured the same way and the table does not rank them.

Human · muscle-driven

MS-Human-700 musculoskeletal model

85 degrees of freedom · 700 muscles · 60.22 kg in the model
Hip
3 coordinates · 35 muscles crossing it
  • hip_flexion_l hinge, -29.8° to 114.6°
  • hip_adduction_l hinge, -48.7° to 28.6°
  • hip_rotation_l hinge, -37.2° to 37.2°
Muscles crossing the hip

Peak isometric force is a model parameter, listed largest first. A muscle can cross more than one coordinate here.

  1. semimem_l2201 N
  2. recfem_l2191.7 N
  3. glmax2_l1406 N
  4. bflh_l1313.2 N
  5. glmed1_l1093.5 N
  6. piri_l1029.8 N
  7. iliacus_l1021.1 N
  8. glmax1_l983.8 N
  9. glmax3_l947.8 N
  10. addlong_l916.8 N
  11. glmed3_l871.2 N
  12. glmed2_l765.1 N
  13. addbrev_l625.8 N
  14. addmagDist_l597.3 N
  15. addmagIsch_l597.3 N
  16. addmagMid_l597.3 N
  17. addmagProx_l597.3 N
  18. semiten_l591.3 N
  19. glmin3_l446.8 N
  20. tfl_l411.2 N
  21. glmin2_l394.8 N
  22. glmin1_l374 N
  23. grac_l281.3 N
  24. Ps_L1_VB_l267.4 N
  25. Ps_L2_TP_l258.6 N
  26. sart_l249.4 N
  27. Ps_L5_VB_l232.9 N
  28. Ps_L4_TP_l202.7 N
  29. Ps_L5_TP_l186.4 N
  30. Ps_L2_L3_IVD_l150.5 N
  31. Ps_L1_L2_IVD_l147.2 N
  32. Ps_L3_TP_l127.8 N
  33. Ps_L4_L5_IVD_l85.1 N
  34. Ps_L1_TP_l77.2 N
  35. Ps_L3_L4_IVD_l45.4 N
Knee
1 coordinate · 8 coupled motions · 13 muscles crossing it
  • knee_angle_l hinge, 0° to 137.5°
What the model couples to the bend

The model drives these from the knee coordinate through equality constraints; nothing commands them separately.

  • knee_angle_l_translation3 slide, -3.7 to 1.9 mm
  • knee_angle_l_translation2 slide, -6.8 to 0 mm
  • knee_angle_l_translation1 slide, 0 to 1.6 mm
  • knee_angle_l_rotation2 rotation, -0.1° to 1.9°
  • knee_angle_l_rotation3 rotation, -15.1° to 0°
  • knee_angle_l_beta_translation2 slide, -40.8 to -10.8 mm
  • knee_angle_l_beta_translation1 slide, -22.8 to 52.4 mm
  • knee_angle_l_beta_rotation1 rotation, -102.7° to 0.6°
Muscles crossing the knee

Peak isometric force is a model parameter, listed largest first. A muscle can cross more than one coordinate here.

  1. vaslat_l5148.8 N
  2. gasmed_l3115.5 N
  3. vasmed_l2747.8 N
  4. semimem_l2201 N
  5. recfem_l2191.7 N
  6. vasint_l1697.4 N
  7. gaslat_l1575.1 N
  8. bflh_l1313.2 N
  9. semiten_l591.3 N
  10. bfsh_l557.1 N
  11. tfl_l411.2 N
  12. grac_l281.3 N
  13. sart_l249.4 N
Ankle and subtalar
2 coordinates · 11 muscles crossing it
  • ankle_angle_l hinge, -39° to 29.8°
  • subtalar_angle_l hinge, -19.5° to 19.5°
Muscles crossing the ankle and subtalar

Peak isometric force is a model parameter, listed largest first. A muscle can cross more than one coordinate here.

  1. soleus_l6194.8 N
  2. gasmed_l3115.5 N
  3. tibpost_l1730.2 N
  4. gaslat_l1575.1 N
  5. tibant_l1227.5 N
  6. perlong_l1115.4 N
  7. fhl_l907.8 N
  8. edl_l603.5 N
  9. perbrev_l521.2 N
  10. fdl_l423.2 N
  11. ehl_l285.9 N

ms_human_700/MS-Human-700.xml at MuJoCo Menagerie 71f066ad · Apache-2.0
MS-Human-700 by the LNS Group (Zuo C, He K, Shao J, Sui Y. Self model for embodied intelligence. ICRA 2024:13062-13069), MuJoCo Menagerie packaging, Apache-2.0.

Humanoid · motor-driven

Unitree G1 (with hands)

43 degrees of freedom · 43 actuators · 34.39 kg in the model
Hip
3 coordinates
  • left_hip_pitch_joint hinge, -145° to 165°model limit 88 N·m (the joint's actuator force range in the model)
  • left_hip_roll_joint hinge, -30° to 170°model limit 139 N·m (the joint's actuator force range in the model)
  • left_hip_yaw_joint hinge, -158° to 158°model limit 88 N·m (the joint's actuator force range in the model)
Knee
1 coordinate
  • left_knee_joint hinge, -5° to 165°model limit 139 N·m (the joint's actuator force range in the model)

Manufacturer quotes 90 / 120 N·m at the knee. Maximum: G1 / EDU; not continuous torque.

Ankle and subtalar
2 coordinates
  • left_ankle_pitch_joint hinge, -50° to 30°model limit 50 N·m (the joint's actuator force range in the model)
  • left_ankle_roll_joint hinge, -15° to 15°model limit 50 N·m (the joint's actuator force range in the model)

unitree_g1/g1_with_hands.xml at MuJoCo Menagerie 71f066ad · BSD-3-Clause
Unitree G1 model from Google DeepMind MuJoCo Menagerie; Unitree Robotics, BSD-3-Clause.

Humanoid · motor-driven

Unitree H1

19 degrees of freedom · 19 actuators · 51.44 kg in the model
Hip
3 coordinates
  • left_hip_yaw hinge, -24.6° to 24.6°model limit 200 N·m (the control range of a direct torque motor in the model)
  • left_hip_roll hinge, -24.6° to 24.6°model limit 200 N·m (the control range of a direct torque motor in the model)
  • left_hip_pitch hinge, -90° to 90°model limit 200 N·m (the control range of a direct torque motor in the model)
Knee
1 coordinate
  • left_knee hinge, -14.9° to 117.5°model limit 300 N·m (the control range of a direct torque motor in the model)

Manufacturer quotes ≈360 N·m at the knee. Maximum joint-unit figure; not continuous output.

Ankle and subtalar
1 coordinate
  • left_ankle hinge, -49.8° to 29.8°model limit 40 N·m (the control range of a direct torque motor in the model)

unitree_h1/h1.xml at MuJoCo Menagerie 71f066ad · BSD-3-Clause
Unitree H1 model from Google DeepMind MuJoCo Menagerie; Unitree Robotics, BSD-3-Clause.

Humanoid · motor-driven

Apptronik Apollo

32 degrees of freedom · 32 actuators · 80.9 kg in the model
Hip
3 coordinates
  • l_hip_ie hinge, -32.5° to 62.5°model limit 120 N·m (the joint's actuator force range in the model)
  • l_hip_aa hinge, -12.5° to 42.5°model limit 494 N·m (the joint's actuator force range in the model)
  • l_hip_fe hinge, -106° to 27.3°model limit 342 N·m (the joint's actuator force range in the model)
Knee
1 coordinate
  • l_knee_fe hinge, 0° to 150°model limit 336 N·m (the joint's actuator force range in the model)

Corpus holds no manufacturer knee-torque figure for this robot.

Ankle and subtalar
2 coordinates
  • l_ankle_ie hinge, -37.5° to 17.5°model limit 120 N·m (the joint's actuator force range in the model)
  • l_ankle_pd hinge, -90° to 25°model limit 150 N·m (the joint's actuator force range in the model)

apptronik_apollo/apptronik_apollo.xml at MuJoCo Menagerie 71f066ad · Apache-2.0
Apptronik Apollo model from Google DeepMind MuJoCo Menagerie, Apache-2.0.