Educational reference only. Not a medical device. Not diagnostic medical advice. Always consult a qualified clinician.

02 / Humanoid · Systems atlas

REFERENCE EDITION / SEPT 2026

Intelligence,
embodied.

Inside the machines that move through our world. Explore physical systems, inspect platform specifications, and follow the engineering.

Technical profiles
06
Cited specifications
28
Primary sources
07
Mapped 3D references
01
PERCEPTION / CONTROL / ACTUATION / POWERSource-linked reference data

Reference intelligence / 06 profiles

Explore the technology.

Inspect the architecture. Compare the specifications.
Trace every data point to its source.

6 of 6 profiles
Manufacturer specificationsSources checked

Research platform

Unitree G1

Compact electric humanoid with a public link-and-joint model. Corpus maps its physical geometry to a common engineering vocabulary.

Height
1.32 m

Standing; G1 and G1 EDU.

Unitree ↗
Mass
≈35 kg

G1 including battery; EDU configurations may be heavier.

Unitree ↗
Degrees of freedom
23–43

23 base; up to 43 on configured EDU.

Unitree ↗
Knee torque
90 / 120 N·m

Maximum: G1 / EDU; not continuous torque.

Unitree ↗
Battery duration
≈2 h

Manufacturer estimate; task dependent.

Unitree ↗
Perception
Depth + LiDAR

Listed sensor package.

Unitree ↗

System architecture

Depth camera + LiDAR → controller → joint motors

  1. 01
    Perception

    Depth and range sensors provide scene information.

  2. 02
    Control

    Joint encoders feed position and force-control loops.

  3. 03
    Actuation

    Permanent-magnet motors drive articulated joints.

  4. 04
    Power

    Quick-release lithium battery supplies the robot.

Kinematic model

Hip, knee, and ankle as the published simulation model declares them

Every value here is read out of a published simulation model, not measured on a person, a robot, or a device. A model's joint limit is what its authors set for simulation; a robot's torque limit in its model can differ from the manufacturer's quoted peak, and a muscle's peak isometric force is a model parameter scaled from cadaver and imaging studies. The models are not measured the same way and the table does not rank them.

Humanoid · motor-driven

43 degrees of freedom · 43 actuators · 34.39 kg in the model
Hip
3 coordinates
  • left_hip_pitch_joint hinge, -145° to 165°model limit 88 N·m (the joint's actuator force range in the model)
  • left_hip_roll_joint hinge, -30° to 170°model limit 139 N·m (the joint's actuator force range in the model)
  • left_hip_yaw_joint hinge, -158° to 158°model limit 88 N·m (the joint's actuator force range in the model)
Knee
1 coordinate
  • left_knee_joint hinge, -5° to 165°model limit 139 N·m (the joint's actuator force range in the model)

Manufacturer quotes 90 / 120 N·m at the knee. Maximum: G1 / EDU; not continuous torque.

Ankle and subtalar
2 coordinates
  • left_ankle_pitch_joint hinge, -50° to 30°model limit 50 N·m (the joint's actuator force range in the model)
  • left_ankle_roll_joint hinge, -15° to 15°model limit 50 N·m (the joint's actuator force range in the model)

unitree_g1/g1_with_hands.xml at MuJoCo Menagerie 71f066ad · BSD-3-Clause
Unitree G1 model from Google DeepMind MuJoCo Menagerie; Unitree Robotics, BSD-3-Clause.

Set beside a human musculoskeletal model →

What to evaluate

  • Measure tracking error under load, not only unloaded motion.
  • Report battery endurance with the task, payload, and duty cycle.
Corpus evaluation questions

Evidence boundaries

  • Specifications vary by G1/EDU configuration. The licensed 3D asset is a specific reference model, not every configuration.
  • Manufacturer maxima are not independently measured Corpus benchmarks.

Side by side / 0 of 3 selected

Compare reference data.

Choose up to three profiles with “Compare”. Different test conditions and device purposes are not equivalent benchmarks.

Spatial reference / Unitree G1

Inside the machine.

Explore physical components and engineering relationships.
Source geometry and schematic internals are identified in the inspector.

Left Knee · Leg actuators schematic · Joint transmissions schematic · Joint lubricant schematic
procedural humanoid fallback
Checking anatomy assets…
Fallback only; physical asset is not displayed.

Engineering pathways

Canonical relationships, resolved onto physical geometry.

These pathways explain dependencies and measurement boundaries. They do not invent Unitree specifications or rank untested products.

Joint, actuator, transmission, and lubricant

Trace how a commanded joint depends on actuation, transmission, lubrication, heat, wear, and context-specific maintenance.

  1. Controlled By

    URDF represents a robot as links connected by joints in a tree; Corpus uses that organization as an ingest-compatible reference, not as its complete internal vocabulary.

    Metric
    joint load
    Boundary
    The canonical Corpus hierarchy is conceptual and procedural; it was not imported from a validated URDF and has no vendor kinematic parameters.
  2. Drives Through

    NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.

    Metric
    backlash
    Boundary
    This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.
  3. Lubricates

    Bearing thermal behavior depends on speed, applied load, lubrication, and external cooling, so lubricant comparisons require operating context.

    Metric
    temperature, service
    Boundary
    SKF guidance is general bearing engineering information, not a test of this canonical humanoid or a product recommendation.

Source custody

Identity, license, integrity, and limits

Unitree G1 model

Unitree G1 model from Google DeepMind MuJoCo Menagerie; copyright HangZhou YuShu TECHNOLOGY CO.,LTD. (Unitree Robotics), BSD-3-Clause.

Open pinned source

License

BSD-3-Clause license retained with the Corpus source lock and release artifact.

Open pinned source

Corpus crosswalk

Vendor-specific source bodies and visible meshes are mapped to the vendor-neutral humanoid:canonical hierarchy by Corpus.

Revision
71f066ad0be9cd271f7ed58c030243ef157af9f4
GLB SHA-256
534d147a3122e945166e914eb6abcdc3078c173c009ded585db66a30c5f40a79
Asset size
2,789,016 bytes
Coverage
71/71 visible meshes mapped
  • The upstream asset is a simplified MJCF robot description, not manufacturer CAD, metrology, a digital twin, or a safety-certified simulation.
  • Corpus roughness, metalness, lighting, shadows, and tone mapping are presentation choices rather than Unitree material specifications.
  • Actuation, transmission, sensing, power, compute, thermal, network, and software use Corpus source-anchored schematic overlays where the upstream asset has no distinct internal mesh. These overlays are explanatory geometry, not Unitree CAD, metrology, component packaging, or proof of exact internal location.
  • Joint metadata describes the source kinematic model; most joints do not have independent visible geometry and are selected through their owning source body.

Guided pathways

Walk a component chain chapter by chapter.

  • The battery pack powers the distribution bus, the battery management system supervises the cells, and the cooling loop controls the pack temperature. Corpus names those five canonical components and two relationships; it stores no cell chemistry, capacity, or pack layout for the G1.

  • Intelligence and control stack4 resolved standards

    Stereo cameras sense for the perception stack, the reasoning model informs the task planner, and the joint controller commands the leg actuators. Corpus names those components and three relationships as the loop this pathway walks. No model weights, benchmark scores, or controller gains are stored.

  • A humanoid joint is a pair of links driven by an actuator through a transmission. Corpus follows the Unitree G1 leg as hip, knee, and ankle links in a URDF-style tree, and the canonical hierarchy names the knee, the leg actuators, the harmonic drives, and the joint lubricant as the chain this pathway walks. The tree is an ingest-compatible reference, not a vendor kinematic model.

Evidence profile: engineering

Evidence and limitations travel with every chain.

ENGINEERING STANDARD

Link-and-joint hierarchy

URDF represents a robot as links connected by joints in a tree; Corpus uses that organization as an ingest-compatible reference, not as its complete internal vocabulary.

The canonical Corpus hierarchy is conceptual and procedural; it was not imported from a validated URDF and has no vendor kinematic parameters.
ENGINEERING STANDARD

Performance depends on test method and operating context

NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.

This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.
MANUFACTURER SPECIFICATION

Bearing temperature is context-dependent

Bearing thermal behavior depends on speed, applied load, lubrication, and external cooling, so lubricant comparisons require operating context.

SKF guidance is general bearing engineering information, not a test of this canonical humanoid or a product recommendation.
FAILURE ANALYSIS

Lithium-ion thermal runaway requires system-level mitigation

Battery safety analysis treats cell propagation, detection, containment, and thermal control as connected system concerns.

The canonical model has no selected cell chemistry, pack topology, capacity, enclosure, or measured abuse-test result.
BENCHMARK EVALUATION

Robot intelligence metrics require platform and task context

Corpus records model version, sensor inputs, compute, task, environment, latency, success metric, failure conditions, and demand before comparisons are meaningful.

This is a Corpus evidence boundary derived from NIST measurement principles; it is not evidence that any named AI model performs best.