Depth and range sensors provide scene information.
02
Control
Joint encoders feed position and force-control loops.
03
Actuation
Permanent-magnet motors drive articulated joints.
04
Power
Quick-release lithium battery supplies the robot.
Kinematic model
Hip, knee, and ankle as the published simulation model declares them
Every value here is read out of a published simulation model, not measured on a person, a robot, or a device. A model's joint limit is what its authors set for simulation; a robot's torque limit in its model can differ from the manufacturer's quoted peak, and a muscle's peak isometric force is a model parameter scaled from cadaver and imaging studies. The models are not measured the same way and the table does not rank them.
Humanoid · motor-driven
43 degrees of freedom · 43 actuators · 34.39 kg in the model
Hip
3 coordinates
left_hip_pitch_joint hinge, -145° to 165°model limit 88 N·m (the joint's actuator force range in the model)
left_hip_roll_joint hinge, -30° to 170°model limit 139 N·m (the joint's actuator force range in the model)
left_hip_yaw_joint hinge, -158° to 158°model limit 88 N·m (the joint's actuator force range in the model)
Knee
1 coordinate
left_knee_joint hinge, -5° to 165°model limit 139 N·m (the joint's actuator force range in the model)
Manufacturer quotes 90 / 120 N·m at the knee. Maximum: G1 / EDU; not continuous torque.
Ankle and subtalar
2 coordinates
left_ankle_pitch_joint hinge, -50° to 30°model limit 50 N·m (the joint's actuator force range in the model)
left_ankle_roll_joint hinge, -15° to 15°model limit 50 N·m (the joint's actuator force range in the model)
unitree_g1/g1_with_hands.xml at MuJoCo Menagerie 71f066ad · BSD-3-Clause Unitree G1 model from Google DeepMind MuJoCo Menagerie; Unitree Robotics, BSD-3-Clause.
These pathways explain dependencies and measurement boundaries. They do not invent Unitree specifications or rank untested products.
Joint, actuator, transmission, and lubricant
Trace how a commanded joint depends on actuation, transmission, lubrication, heat, wear, and context-specific maintenance.
Controlled By
URDF represents a robot as links connected by joints in a tree; Corpus uses that organization as an ingest-compatible reference, not as its complete internal vocabulary.
Metric
joint load
Boundary
The canonical Corpus hierarchy is conceptual and procedural; it was not imported from a validated URDF and has no vendor kinematic parameters.
Drives Through
NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.
Metric
backlash
Boundary
This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.
Lubricates
Bearing thermal behavior depends on speed, applied load, lubrication, and external cooling, so lubricant comparisons require operating context.
Metric
temperature, service
Boundary
SKF guidance is general bearing engineering information, not a test of this canonical humanoid or a product recommendation.
Source custody
Identity, license, integrity, and limits
Unitree G1 model
Unitree G1 model from Google DeepMind MuJoCo Menagerie; copyright HangZhou YuShu TECHNOLOGY CO.,LTD. (Unitree Robotics), BSD-3-Clause.
The upstream asset is a simplified MJCF robot description, not manufacturer CAD, metrology, a digital twin, or a safety-certified simulation.
Corpus roughness, metalness, lighting, shadows, and tone mapping are presentation choices rather than Unitree material specifications.
Actuation, transmission, sensing, power, compute, thermal, network, and software use Corpus source-anchored schematic overlays where the upstream asset has no distinct internal mesh. These overlays are explanatory geometry, not Unitree CAD, metrology, component packaging, or proof of exact internal location.
Joint metadata describes the source kinematic model; most joints do not have independent visible geometry and are selected through their owning source body.
The battery pack powers the distribution bus, the battery management system supervises the cells, and the cooling loop controls the pack temperature. Corpus names those five canonical components and two relationships; it stores no cell chemistry, capacity, or pack layout for the G1.
Stereo cameras sense for the perception stack, the reasoning model informs the task planner, and the joint controller commands the leg actuators. Corpus names those components and three relationships as the loop this pathway walks. No model weights, benchmark scores, or controller gains are stored.
A humanoid joint is a pair of links driven by an actuator through a transmission. Corpus follows the Unitree G1 leg as hip, knee, and ankle links in a URDF-style tree, and the canonical hierarchy names the knee, the leg actuators, the harmonic drives, and the joint lubricant as the chain this pathway walks. The tree is an ingest-compatible reference, not a vendor kinematic model.
Evidence profile: engineering
Evidence and limitations travel with every chain.
ENGINEERING STANDARD
Link-and-joint hierarchy
URDF represents a robot as links connected by joints in a tree; Corpus uses that organization as an ingest-compatible reference, not as its complete internal vocabulary.
The canonical Corpus hierarchy is conceptual and procedural; it was not imported from a validated URDF and has no vendor kinematic parameters.ENGINEERING STANDARD
Performance depends on test method and operating context
NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.
This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.MANUFACTURER SPECIFICATION
Bearing temperature is context-dependent
Bearing thermal behavior depends on speed, applied load, lubrication, and external cooling, so lubricant comparisons require operating context.
SKF guidance is general bearing engineering information, not a test of this canonical humanoid or a product recommendation.FAILURE ANALYSIS
Battery safety analysis treats cell propagation, detection, containment, and thermal control as connected system concerns.
The canonical model has no selected cell chemistry, pack topology, capacity, enclosure, or measured abuse-test result.BENCHMARK EVALUATION
Robot intelligence metrics require platform and task context
Corpus records model version, sensor inputs, compute, task, environment, latency, success metric, failure conditions, and demand before comparisons are meaningful.
This is a Corpus evidence boundary derived from NIST measurement principles; it is not evidence that any named AI model performs best.