Educational reference only. Not a medical device. Not diagnostic medical advice. Always consult a qualified clinician.

← Humanoid · Reviewed engineering pathway

Battery, power, and thermal behavior

Follow the component chain through its place on the platform, maintenance boundaries, engineering evidence, and the standards resolved for it. Standards replace the trial shelf: each one is pinned to a published edition and year before this page can exist.

Reviewed September 3, 2026 · Re-review due September 3, 2027 · 3 resolved standards

Chapter 1 · definition

Start with the power chain

The battery pack powers the distribution bus, the battery management system supervises the cells, and the cooling loop controls the pack temperature. Corpus names those five canonical components and two relationships; it stores no cell chemistry, capacity, or pack layout for the G1.

Platform focusBattery pack schematic

Chapter 2 · anatomy

Where the chain sits on the platform

The pack, cells, management system, distribution, and cooling loop are schematic nodes placed in the torso, so the torso shell is highlighted for location. The source mesh has no geometry for any of them.

Platform focusBattery cells schematicBattery pack schematicBattery-management system schematicPower distribution schematicCooling system schematicTorso
Engineering evidence
  • engineering standard

    Performance depends on test method and operating context. NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.

    This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.

Referenced records
  • rel:h2-power
  • rel:h2-thermal
  • ev:robot-metrics
Coverage limit

No pack specification is stored. Runtime, cell temperature, and operating temperature are recorded as metrics with no values.

Chapter 3 · interventions

Maintenance and intervention boundaries

Charge management, thermal limits, and cell temperature monitoring are the interventions on this chain. Corpus records the risk context for lithium cells under load and the metrics an intervention moves. It sets no limit values and no charge profile.

Platform focusCooling system schematicBattery-management system schematic
Runtimeminutes
higher better · capacity and duty cycle dependent
Cell temperaturedeg C
context dependent · chemistry specific
Operating temperaturedeg C
context dependent · load speed dependent
Engineering evidence
  • failure analysis

    Lithium-ion thermal runaway requires system-level mitigation. Battery safety analysis treats cell propagation, detection, containment, and thermal control as connected system concerns.

    The canonical model has no selected cell chemistry, pack topology, capacity, enclosure, or measured abuse-test result.

Referenced records
  • rel:h2-thermal
  • ev:battery-risk
  • metric:runtime
  • metric:cell-temperature
  • metric:temperature
Coverage limit

Limits belong to the cell datasheet and the pack design, neither of which Corpus holds.

Chapter 4 · evidence

What the engineering evidence covers

Two engineering evidence records back this chain: the robot performance metric vocabulary and the battery risk context record. Both are context, not measurements of this platform.

Engineering evidence
  • engineering standard

    Performance depends on test method and operating context. NIST develops test methods and performance metrics covering robot mobility, manipulation, sensing, energy, communications, interfaces, logistics, and safety.

    This source defines measurement practice; it does not supply performance values for the Corpus canonical humanoid.

  • failure analysis

    Lithium-ion thermal runaway requires system-level mitigation. Battery safety analysis treats cell propagation, detection, containment, and thermal control as connected system concerns.

    The canonical model has no selected cell chemistry, pack topology, capacity, enclosure, or measured abuse-test result.

Referenced records
  • ev:robot-metrics
  • ev:battery-risk
  • src:nist-response-robot
  • src:nist-robotics
  • src:nasa-thermal-runaway

Chapter 5 · standards

Standards resolved for this chain

IEC 62133-2:2017 sets the safety tests for the lithium cells and packs a humanoid carries. IEC 60529 (edition 2.2, 2013) defines the ingress protection rating of the enclosure around them. ISO 13482:2014 is the personal care robot safety standard that treats battery and thermal hazards for robots operating near people. Each is pinned to a published edition and year.

StandardEditionYearStatusApplies
IEC 62133-2:2017Secondary cells and batteries containing alkaline or other non-acid electrolytes. Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications. Part 2: Lithium systems1.02017resolveddirect
IEC 60529:1989+AMD1:1999+AMD2:2013Degrees of protection provided by enclosures (IP Code)2.22013resolveddirect
ISO 13482:2014Robots and robotic devices. Safety requirements for personal care robots12014resolvedadjacent

Resolved means the published edition and year were identified and pinned. Adjacent means the standard is written for a neighbouring robot class and is cited as the reference point, not as a certification.

Coverage limit

ISO 13482 covers three robot types and a general-purpose humanoid fits none of them exactly, so its applicability is marked adjacent.