Cochlear implant: sound to nerve
Follow the device chain through where it meets the body, what can be adjusted, the public device and regulatory record, and the FDA product codes resolved for it. Product codes replace the trial shelf: every cited code is reconciled against the committed openFDA pack, and at least one carries a premarket record on file before this page can exist.
Chapter 1 · definition
Start with the signal chain
A cochlear implant system is a microphone that picks up sound, a sound processor that selects and arranges it, a transmitting coil and an implanted receiver-stimulator that turn the processed signal into electrical impulses, and an electrode array that carries those impulses to the cochlear nerve. Corpus names those five components and the three relationships between them; it stores no manufacturer's electrode geometry or coding strategy.
- device registration
Component chain of a cochlear implant system. A cochlear implant system is described as a microphone that picks up sound, a speech processor that selects and arranges it, a transmitter and receiver-stimulator that convert the processed signal into electrical impulses, and an electrode array that carries those impulses to the auditory nerve.
- ev:t1-topology
- rel:t1-sense
- rel:t1-link
- rel:t1-stimulate
- nidcd-cochlear-implant-overview-2026-07-22
- accessgudid-device-identification
Chapter 2 · anatomy
Where the chain meets the body
The microphone, processor, and coil are worn outside the body. The receiver-stimulator sits under the skin against the skull, so the skeletal system is highlighted for its anchor, and the electrode array enters the cochlea to reach the cochlear nerve, marked here on the brain. Corpus has no cochlear mesh, so the interface node is an orientation marker placed on a reviewed anchor, not cochlear anatomy.
The overlay is placed on reviewed attachment anchors that resolve to whole atlas structures. Anchor precision is region-level or orientation-only, so the rendered position indicates a body region, not a surgical location.
Device geometry in this overlay is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.
- rel:t1-link
- rel:t1-stimulate
- lim:anchor-precision
- lim:corpus-schematic-geometry
Anchor precision is region-level. The rendered position indicates the side of the head and the nerve target, not a surgical location, and no cochlear geometry exists in the atlas.
Chapter 3 · interventions
What can be changed from outside
Everything adjustable lives in the worn parts: the processor's program, the input range it maps, the stimulation rate it commands, and how many hours a day it is worn. The implanted parts take their power and instructions across the skin. An implant gives a useful representation of sound and can help a person understand speech; it does not restore normal hearing, and Corpus publishes no fitting procedure, program value, or candidacy criterion.
- Input sound rangedB SPL
- context dependent · device and program specific
- Stimulation ratepulses per second
- context dependent · device and program specific
- Daily wear timehours
- context dependent · user specific
- device registration
The worn parts carry the power and the processing. The microphone, processor, and power source are worn outside the body and are removable; the implanted receiver-stimulator and electrode array take their power and their instructions across the skin from the external unit.
- clinical guideline
An implant does not restore normal hearing. A cochlear implant does not restore normal hearing. It gives a useful representation of sounds in the environment and can help a person understand speech, which is a different thing from repairing the cochlea.
No vendor stimulation parameters, control gains, programming values, or fitting procedures are published here. Those are device-specific and clinician-set.
This pack orients a reader to how a configuration is put together and what the public record says about it. It is not clinical guidance and cannot inform device selection, implantation, or programming.
- ev:t1-external-power
- ev:t1-not-normal-hearing
- rel:t1-power
- metric:t1-input-range
- metric:t1-rate
- metric:t1-wear-time
- lim:no-vendor-parameters
- lim:not-clinical-guidance
Programming values, battery chemistry, service intervals, and wear schedules belong to the device and the clinic. Corpus records the division between worn and implanted parts, nothing more.
Chapter 4 · evidence
What the public record covers
The chain is described by a device registration record and a national institute overview. The outcome statement, that an implant does not restore normal hearing, comes from that overview and is the only outcome claim in this pack. Post-market reports filed against the implanted category and the recall records on file are attached as counts: they are reports received across every manufacturer over the life of the database, not events that occurred and not a rate.
- Reports filed as malfunctionreports received
- context dependent · 32674
- Recall records on filerecall records
- context dependent · 32
- Speech understanding
- context dependent · individually variable
- device registration
Component chain of a cochlear implant system. A cochlear implant system is described as a microphone that picks up sound, a speech processor that selects and arranges it, a transmitter and receiver-stimulator that convert the processed signal into electrical impulses, and an electrode array that carries those impulses to the auditory nerve.
- clinical guideline
An implant does not restore normal hearing. A cochlear implant does not restore normal hearing. It gives a useful representation of sounds in the environment and can help a person understand speech, which is a different thing from repairing the cochlea.
- adverse event report
Post-market reports filed against the cochlear implant category. Reports filed with the FDA against the implanted cochlear implant category are attached to this record, broken down by the event type the reporter selected.
- recall
Recall records against the cochlear implant category. Device recall records filed against the implanted cochlear implant category are attached to this record. A recall is a correction or removal action, and its presence in the record is a sign that a problem was found and acted on.
MAUDE is passive surveillance. Report counts have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.
Corpus publishes no efficacy estimate, outcome score, or candidacy criterion for any configuration in this pack. Outcomes vary between individuals and are not derivable from the records cited here.
- ev:t1-topology
- ev:t1-not-normal-hearing
- ev:t1-postmarket
- ev:t1-recalls
- metric:t1-malfunction-reports
- metric:t1-recall-records
- metric:t1-outcome
- lim:passive-surveillance
- lim:no-outcome-estimate
No speech-perception score, no comparison between devices, and no individual outcome is published. MAUDE counts have no denominator.
Chapter 5 · regulatory
How the category reaches the market
The implanted cochlear implant category and the combined electric-acoustic category are class III devices whose route to market is premarket approval; the approval numbers on file are attached. The powered electrode-array insertion system used at surgery is a separate category that reaches the market by premarket notification, and its clearance numbers are attached. Every count here covers the whole category from every manufacturer, and an approval speaks to a specific application from a specific applicant.
- Premarket approvals on fileapproved applications
- context dependent · 9
- regulatory approval
Implanted cochlear implants reach the market through premarket approval. The implanted cochlear implant category and the combined electric-acoustic category are class III devices whose route to market is premarket approval. The approval numbers on file for each are attached to this record rather than described.
| Product code | Class | Market pathway | Premarket records | Recalls | Reports |
|---|---|---|---|---|---|
| MCMImplant, Cochlear | 3 | Premarket approval | 9P000015, P000025, P200021, P830069, P840024, P890027, P940022, P960058, P970051 | 32 | 75,973 |
| PGQCochlear Implant With Combined Electrical Stimulation And Acoustic Amplification | 3 | Premarket approval | 2P000025, P130016 | 3 | 268 |
| QQHPowered Insertion System For A Cochlear Implant Electrode Array | 2 | Premarket notification (510(k)) | 2DEN190055, K252339 | 1 | 12 |
An FDA product code names a regulatory category, not a product. Every count attached to a code covers all devices cleared or approved in that category, from every manufacturer.
- fda:cochlear-implant:MCM
- fda:cochlear-implant:PGQ
- fda:cochlear-implant:QQH
- ev:t1-regulatory
- metric:t1-approvals
- lim:category-not-product
- openfda-device-apis
- fda-cochlear-implant-hub-2026-07-22
An approval does not carry over to devices outside the application it names, and it says nothing about how a device performs for an individual.