Educational reference only. Not a medical device. Not diagnostic medical advice. Always consult a qualified clinician.

← Transhuman · Cochlear implant · Reviewed device pathway

Cochlear implant: sound to nerve

Follow the device chain through where it meets the body, what can be adjusted, the public device and regulatory record, and the FDA product codes resolved for it. Product codes replace the trial shelf: every cited code is reconciled against the committed openFDA pack, and at least one carries a premarket record on file before this page can exist.

Reviewed September 3, 2026 · Re-review due September 3, 2027 · 3 product codes cited, 3 with premarket records

Chapter 1 · definition

Start with the signal chain

A cochlear implant system is a microphone that picks up sound, a sound processor that selects and arranges it, a transmitting coil and an implanted receiver-stimulator that turn the processed signal into electrical impulses, and an electrode array that carries those impulses to the cochlear nerve. Corpus names those five components and the three relationships between them; it stores no manufacturer's electrode geometry or coding strategy.

Configuration focusMicrophone (schematic)External sound processor (schematic)Transmitting coil (schematic)Implanted receiver-stimulator (schematic)Intracochlear electrode array (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Device and regulatory evidence
  • device registration

    Component chain of a cochlear implant system. A cochlear implant system is described as a microphone that picks up sound, a speech processor that selects and arranges it, a transmitter and receiver-stimulator that convert the processed signal into electrical impulses, and an electrode array that carries those impulses to the auditory nerve.

    This is component topology only. It describes no manufacturer's design, electrode geometry, or coding strategy, and the Corpus overlay renders that chain schematically.

Referenced records

Chapter 2 · anatomy

Where the chain meets the body

The microphone, processor, and coil are worn outside the body. The receiver-stimulator sits under the skin against the skull, so the skeletal system is highlighted for its anchor, and the electrode array enters the cochlea to reach the cochlear nerve, marked here on the brain. Corpus has no cochlear mesh, so the interface node is an orientation marker placed on a reviewed anchor, not cochlear anatomy.

Configuration focusImplanted receiver-stimulator (schematic)Intracochlear electrode array (schematic)Cochlear interface (schematic)Cochlear nerve target (schematic)Skeleton (atlas)Brain (atlas)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Declared limitations

The overlay is placed on reviewed attachment anchors that resolve to whole atlas structures. Anchor precision is region-level or orientation-only, so the rendered position indicates a body region, not a surgical location.

Device geometry in this overlay is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.

Referenced records
  • rel:t1-link
  • rel:t1-stimulate
  • lim:anchor-precision
  • lim:corpus-schematic-geometry
Coverage limit

Anchor precision is region-level. The rendered position indicates the side of the head and the nerve target, not a surgical location, and no cochlear geometry exists in the atlas.

Chapter 3 · interventions

What can be changed from outside

Everything adjustable lives in the worn parts: the processor's program, the input range it maps, the stimulation rate it commands, and how many hours a day it is worn. The implanted parts take their power and instructions across the skin. An implant gives a useful representation of sound and can help a person understand speech; it does not restore normal hearing, and Corpus publishes no fitting procedure, program value, or candidacy criterion.

Configuration focusExternal sound processor (schematic)Processor battery (schematic)Transmitting coil (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Input sound rangedB SPL
context dependent · device and program specific
Stimulation ratepulses per second
context dependent · device and program specific
Daily wear timehours
context dependent · user specific
Device and regulatory evidence
  • device registration

    The worn parts carry the power and the processing. The microphone, processor, and power source are worn outside the body and are removable; the implanted receiver-stimulator and electrode array take their power and their instructions across the skin from the external unit.

    Corpus records the division between worn and implanted parts, not battery chemistry, capacity, service interval, or wear schedule for any product.

  • clinical guideline

    An implant does not restore normal hearing. A cochlear implant does not restore normal hearing. It gives a useful representation of sounds in the environment and can help a person understand speech, which is a different thing from repairing the cochlea.

    Results vary between individuals. Corpus publishes no speech-perception score, no candidacy criterion, and no comparison between devices.

Declared limitations

No vendor stimulation parameters, control gains, programming values, or fitting procedures are published here. Those are device-specific and clinician-set.

This pack orients a reader to how a configuration is put together and what the public record says about it. It is not clinical guidance and cannot inform device selection, implantation, or programming.

Referenced records
  • ev:t1-external-power
  • ev:t1-not-normal-hearing
  • rel:t1-power
  • metric:t1-input-range
  • metric:t1-rate
  • metric:t1-wear-time
  • lim:no-vendor-parameters
  • lim:not-clinical-guidance
Coverage limit

Programming values, battery chemistry, service intervals, and wear schedules belong to the device and the clinic. Corpus records the division between worn and implanted parts, nothing more.

Chapter 4 · evidence

What the public record covers

The chain is described by a device registration record and a national institute overview. The outcome statement, that an implant does not restore normal hearing, comes from that overview and is the only outcome claim in this pack. Post-market reports filed against the implanted category and the recall records on file are attached as counts: they are reports received across every manufacturer over the life of the database, not events that occurred and not a rate.

Configuration focusImplanted receiver-stimulator (schematic)Intracochlear electrode array (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Reports filed as malfunctionreports received
context dependent · 32674
Recall records on filerecall records
context dependent · 32
Speech understanding
context dependent · individually variable
Device and regulatory evidence
  • device registration

    Component chain of a cochlear implant system. A cochlear implant system is described as a microphone that picks up sound, a speech processor that selects and arranges it, a transmitter and receiver-stimulator that convert the processed signal into electrical impulses, and an electrode array that carries those impulses to the auditory nerve.

    This is component topology only. It describes no manufacturer's design, electrode geometry, or coding strategy, and the Corpus overlay renders that chain schematically.

  • clinical guideline

    An implant does not restore normal hearing. A cochlear implant does not restore normal hearing. It gives a useful representation of sounds in the environment and can help a person understand speech, which is a different thing from repairing the cochlea.

    Results vary between individuals. Corpus publishes no speech-perception score, no candidacy criterion, and no comparison between devices.

  • adverse event report

    Post-market reports filed against the cochlear implant category. Reports filed with the FDA against the implanted cochlear implant category are attached to this record, broken down by the event type the reporter selected.

    These are reports received across every manufacturer in the category over the life of the database. They are not events that occurred, not a rate, and not evidence that a device caused any outcome.

  • recall

    Recall records against the cochlear implant category. Device recall records filed against the implanted cochlear implant category are attached to this record. A recall is a correction or removal action, and its presence in the record is a sign that a problem was found and acted on.

    Corpus republishes the recall classification, reason, and status. Firm addresses and contact details are removed, and no recall here is matched to an individual implant.

Declared limitations

MAUDE is passive surveillance. Report counts have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.

Corpus publishes no efficacy estimate, outcome score, or candidacy criterion for any configuration in this pack. Outcomes vary between individuals and are not derivable from the records cited here.

Referenced records
  • ev:t1-topology
  • ev:t1-not-normal-hearing
  • ev:t1-postmarket
  • ev:t1-recalls
  • metric:t1-malfunction-reports
  • metric:t1-recall-records
  • metric:t1-outcome
  • lim:passive-surveillance
  • lim:no-outcome-estimate
Coverage limit

No speech-perception score, no comparison between devices, and no individual outcome is published. MAUDE counts have no denominator.

Chapter 5 · regulatory

How the category reaches the market

The implanted cochlear implant category and the combined electric-acoustic category are class III devices whose route to market is premarket approval; the approval numbers on file are attached. The powered electrode-array insertion system used at surgery is a separate category that reaches the market by premarket notification, and its clearance numbers are attached. Every count here covers the whole category from every manufacturer, and an approval speaks to a specific application from a specific applicant.

Premarket approvals on fileapproved applications
context dependent · 9
Device and regulatory evidence
  • regulatory approval

    Implanted cochlear implants reach the market through premarket approval. The implanted cochlear implant category and the combined electric-acoustic category are class III devices whose route to market is premarket approval. The approval numbers on file for each are attached to this record rather than described.

    An approval covers a specific application from a specific applicant. It says nothing about how a device performs for an individual and does not carry over to devices outside the category.

Product codeClassMarket pathwayPremarket recordsRecallsReports
MCMImplant, Cochlear3Premarket approval9P000015, P000025, P200021, P830069, P840024, P890027, P940022, P960058, P9700513275,973
PGQCochlear Implant With Combined Electrical Stimulation And Acoustic Amplification3Premarket approval2P000025, P1300163268
QQHPowered Insertion System For A Cochlear Implant Electrode Array2Premarket notification (510(k))2DEN190055, K252339112

A product code is a regulatory category, not a product; every count covers all devices in the category from every manufacturer. Premarket records are approvals plus clearances on file. Reports are MAUDE reports received, which are not events that occurred and carry no denominator. Retrieved from openFDA 2026-07-22.

Declared limitations

An FDA product code names a regulatory category, not a product. Every count attached to a code covers all devices cleared or approved in that category, from every manufacturer.

Coverage limit

An approval does not carry over to devices outside the application it names, and it says nothing about how a device performs for an individual.