Educational reference only. Not a medical device. Not diagnostic medical advice. Always consult a qualified clinician.

Transhuman · composed onto canonical human

Powered lower-limb prosthesis

A Human base model with an anchored transfemoral prosthesis overlay: a socket over the residual limb, a powered knee and ankle, load and position sensing, and a controller that coordinates them across the gait cycle.

All configurations

Socket · Residual limb interface · str femur l · str skin
Powered lower-limb prosthesis on BodyParts3D meshes
Checking anatomy assets…
Device geometry is Corpus-authored schematic, not vendor CAD.

Configuration pathway

Socket to ground: the powered limb control loop

Follow load from the residual limb through the socket into a sensing and control loop that drives powered knee and ankle motion, and see how differently this configuration is regulated from the two implants.

Interfaces with residual limb interface

A powered transfemoral prosthesis is built as a socket carrying load from the residual limb, a powered knee and a powered ankle joined by a pylon, a foot, load sensing, an onboard controller, and a battery. The open-source reference platform documents that architecture in the open.

Measured by
Load transfer surface: fit-specific.
Boundary
The open-source reference documents one research platform. Corpus renders the architecture schematically and carries no commercial product's mass, geometry, control law, or joint torque.
  • The overlay is placed on reviewed attachment anchors that resolve to whole atlas structures. Anchor precision is region-level or orientation-only, so the rendered position indicates a body region, not a surgical location.
  • Device geometry in this overlay is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.
  • This pack orients a reader to how a configuration is put together and what the public record says about it. It is not clinical guidance and cannot inform device selection, implantation, or programming.
device registration

Component chain of a powered lower-limb prosthesis

A powered transfemoral prosthesis is built as a socket carrying load from the residual limb, a powered knee and a powered ankle joined by a pylon, a foot, load sensing, an onboard controller, and a battery. The open-source reference platform documents that architecture in the open.

The open-source reference documents one research platform. Corpus renders the architecture schematically and carries no commercial product's mass, geometry, control law, or joint torque.

Public regulatory and safety record

What the FDA record actually says

Every number below is read out of the openFDA device databases at build time. A product code names a regulatory category, not a product, so each row covers every device cleared or approved in that category, from every manufacturer.

Component, External, Limb, Ankle/Foot ISH

Route to market
Class I, general controls
Premarket approvals on file
None on file
Recall records
13
Reports received
95 (injury 48, malfunction 42, other 2, unspecified 3)
MAUDE is passive surveillance. These counts are reports received, not events that occurred. They have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.

Recall pinning coverage: 1 of 13 listed recalls are pinned to a part. Not pinned yet: Z-0209-2016, Z-0362-2014, Z-0388-06, Z-0445-2007, Z-0468-2007, Z-0936-2014, Z-1083-04, Z-1149-2007, Z-1288-2015, Z-1379-04, Z-1650-2012, Z-1906-2023.

What the reports are coded as

Device problems

  1. Naturally Worn18
  2. Fracture15
  3. Break13
  4. Insufficient Device Problem Information9
  5. Component(s), broken4
  6. Explanted4
  7. Device Slipped3
  8. Material Separation3
  9. Misassembled3
  10. Product Quality Problem3
  11. Component Incompatible2

2 code entries among the most frequent record that no specific code applied.

Patient problems

  1. Fall28
  2. Pain12HP:0012531
  3. Bone Fracture(s)9
  4. Injury7
  5. Hip Fracture6
  6. Surgical procedure5
  7. Bruise/Contusion4
  8. Limb Fracture4
  9. Tissue Damage4

29 code entries among the most frequent record that no specific code applied.

The 12 most frequent device-problem and patient-problem codes. One report can carry several codes, so they do not sum to the report total. Codes marked uncoded record that no specific code applied. An HPO term is shown only where the FDA code is, word for word, an HPO label or exact synonym; that is a vocabulary match, not a clinical mapping.

Pinning coverage: 0 of 11 listed coded terms are pinned to a part. Not pinned to a part yet: Naturally Worn, Fracture, Break, Insufficient Device Problem Information, Component(s), broken, Explanted, Device Slipped, Material Separation, Misassembled, Product Quality Problem, Component Incompatible. Uncoded entries: Adverse Event Without Identified Device or Use Problem.

Labeled device identifiers: 24,391
MRI safety labeling
Labeling does not contain MRI Safety Information 24,391
Labelers with the most identifiers
COLLEGE PARK INDUSTRIES, INC. 21,363 · Alps South, LLC 1,412 · TRULIFE LIMITED 1,309 · C Lindhextend AB 286 · Streifeneder ortho.production GmbH 8 · Axiles Bionics 6 · BROWNMED, INC. 4 · Impulse Technology, LLC. 2
Most common device types (GMDN)
Mechanical-resistance external ankle-foot prosthesis 23,204 · Hydraulic/pneumatic external ankle-foot prosthesis 702 · Mechatronic external ankle-foot prosthesis 360 · External lower-limb prosthesis structural/alignment component 56 · External limb prosthesis finishing component, non-customized 36 · Ankle/foot orthosis 21 · External lower-limb prosthesis suspensory component, non-powered 7 · Toe intraoperative aligner 4
AccessGUDID lists a device identifier for every labeled version and package, including external processors, batteries, cables, and accessories filed under the product code. The total counts labeled identifiers, not distinct products and not devices implanted. MRI safety is the labeling status the manufacturer submitted, not a clearance for any scan.

Joint, Knee, External Limb Component ISY

Route to market
Class I, general controls
Premarket approvals on file
None on file
Recall records
17
Reports received
499 (death 3, injury 257, malfunction 227, other 9, unspecified 3)
MAUDE is passive surveillance. These counts are reports received, not events that occurred. They have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.

Recall pinning coverage: 2 of 15 listed recalls are pinned to a part. Not pinned yet: Z-0537-2010, Z-0608-2016, Z-0759-2007, Z-0815-03, Z-0826-2019, Z-0827-2019, Z-0828-2019, Z-0965-2012, Z-1076-2007, Z-1197-06, Z-1198-06, Z-1199-06, Z-1200-06.

What the reports are coded as

Device problems

  1. Mechanical Problem168
  2. Unintended System Motion70
  3. Device Operates Differently Than Expected66
  4. Device Handling Problem40
  5. Insufficient Device Problem Information30
  6. Physical Resistance/Sticking23
  7. Break10
  8. Loose or Intermittent Connection9
  9. Device Slipped8
  10. Fracture6

40 code entries among the most frequent record that no specific code applied.

Patient problems

  1. Fall196
  2. Bone Fracture(s)68
  3. Limb Fracture41
  4. Hip Fracture26
  5. Injury26
  6. Bruise/Contusion25
  7. Fracture, Arm15
  8. Concussion13
  9. Laceration(s)13

206 code entries among the most frequent record that no specific code applied.

The 12 most frequent device-problem and patient-problem codes. One report can carry several codes, so they do not sum to the report total. Codes marked uncoded record that no specific code applied. An HPO term is shown only where the FDA code is, word for word, an HPO label or exact synonym; that is a vocabulary match, not a clinical mapping.

Pinning coverage: 0 of 10 listed coded terms are pinned to a part. Not pinned to a part yet: Mechanical Problem, Unintended System Motion, Device Operates Differently Than Expected, Device Handling Problem, Insufficient Device Problem Information, Physical Resistance/Sticking, Break, Loose or Intermittent Connection, Device Slipped, Fracture. Uncoded entries: Adverse Event Without Identified Device or Use Problem, Unknown (for use when the device problem is not known).

Labeled device identifiers: 121
MRI safety labeling
Labeling does not contain MRI Safety Information 121
Labelers with the most identifiers
COLLEGE PARK INDUSTRIES, INC. 43 · OSSUR AMERICAS, INC. 20 · TEH LIN PROSTHETIC & ORTHOPAEDIC INC. 19 · BROWNMED, INC. 11 · Streifeneder ortho.production GmbH 10 · TRULIFE LIMITED 6 · CYPRESS ADAPTIVE, LLC 5 · DJO, LLC 4
Most common device types (GMDN)
Mechatronic external knee prosthesis 31 · Mechanical-resistance external knee prosthesis 30 · Hydraulic/pneumatic external knee prosthesis 27 · Hip/knee orthosis 11 · Knee support orthosis 9 · Motorized external knee prosthesis 5 · Ankle-disarticulation prosthesis 2 · External lower-limb prosthesis suspensory component, non-powered 2
AccessGUDID lists a device identifier for every labeled version and package, including external processors, batteries, cables, and accessories filed under the product code. The total counts labeled identifiers, not distinct products and not devices implanted. MRI safety is the labeling status the manufacturer submitted, not a clearance for any scan.
  • Educational reference only. Not a medical device, not a fitting or alignment tool, and not a prescription for any component.
  • All geometry is Corpus-authored and generic. It is not the Open-Source Leg CAD and not any commercial prosthesis; component sizes, masses, and joint ranges differ between products.
  • The Human base asset has no separable lower limb, so the prosthesis is drawn over an intact biological leg rather than replacing it. Corpus makes the biological envelope translucent to keep the device legible; it is not depicting an amputation.
  • Socket fit, residual-limb length, soft-tissue volume, and suspension method differ for every person and are not modelled.
  • Powered and passive prostheses behave differently. Nothing here establishes that a powered device is appropriate, available, or better for a given person or activity.