Follow the device chain through where it meets the body, what can be adjusted, the public device and regulatory record, and the FDA product codes resolved for it. Product codes replace the trial shelf: every cited code is reconciled against the committed openFDA pack, and at least one carries a premarket record on file before this page can exist.

Reviewed September 3, 2026 · Re-review due September 3, 2027 · 6 product codes cited, 4 with premarket records

Chapter 1 · definition

Start with the stimulation chain

A deep-brain stimulation system is registered as an implanted pulse generator placed in a chest pocket, an extension lead tunnelled under the skin, and an electrode passing through a cranial entry point to a deep brain target. Settings are changed from outside the body with a clinician programmer. Corpus names those components and the relationships that power, program, route, and interface them; it carries no lead trajectory, contact spacing, or target coordinate.

Configuration focusGenerator power cell (schematic)Implanted pulse generator (schematic)Stimulation controller (schematic)Extension lead (schematic)Cranial entry and lead anchor (schematic)Intracranial electrode (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Device and regulatory evidence
  • device registration

    Component chain of a deep-brain stimulation system. A deep-brain stimulation system is registered as an implanted pulse generator placed in a chest pocket, an extension lead tunnelled under the skin, and an electrode passing through a cranial entry point to a deep brain target. Stimulation settings are changed from outside the body with a clinician programmer.

    This is component topology only. Corpus renders the chain schematically and carries no lead trajectory, contact spacing, or target coordinate for any system.

Referenced records

Chapter 2 · anatomy

Where the chain sits in the body

The generator and its battery are anchored to the chest wall and the lead runs under the skin to a cranial entry point, so the skeletal system is highlighted for those anchors. The electrode ends at a deep target inside the basal ganglia, which is highlighted for location. The overlay is schematic and its anchors resolve to whole atlas structures, so the rendered path indicates a region, not a surgical plan.

Configuration focusImplanted pulse generator (schematic)Extension lead (schematic)Cranial entry and lead anchor (schematic)Intracranial electrode (schematic)Deep stimulation target (schematic)Skeleton (atlas)Basal ganglia (atlas)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Lead path
context dependent · surgical plan specific
Declared limitations

The overlay is placed on reviewed attachment anchors that resolve to whole atlas structures. Anchor precision is region-level or orientation-only, so the rendered position indicates a body region, not a surgical location.

Device geometry in this overlay is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.

Referenced records
  • rel:t2-route
  • rel:t2-interface
  • metric:t2-lead-path
  • lim:anchor-precision
  • lim:corpus-schematic-geometry
Coverage limit

The target node marks a region of the basal ganglia. No nucleus-level geometry exists in the atlas and no trajectory is stored.

Chapter 3 · interventions

What the clinician adjusts

Amplitude, frequency, and the active contacts are set from the clinician programmer and stored on the generator; the generator's service interval depends on those settings and its battery chemistry. Continuous stimulation modulates the activity of a circuit. It does not repair, replace, or regrow tissue, and stopping stimulation stops the effect. Corpus publishes no programming value and no fitting procedure.

Configuration focusExternal programmer (schematic)Stimulation controller (schematic)Implanted pulse generator (schematic)Intracranial electrode (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Stimulation amplitudemA or V
context dependent · clinician set, device specific
Stimulation frequencyHz
context dependent · clinician set, device specific
Electrode contactscontacts
context dependent · device specific
Generator service intervalyears
context dependent · settings and chemistry dependent
Declared limitations

No vendor stimulation parameters, control gains, programming values, or fitting procedures are published here. Those are device-specific and clinician-set.

Continuous stimulation modulates the activity of a circuit. It does not repair, replace, or regrow tissue, and stopping stimulation removes the effect.

This pack orients a reader to how a configuration is put together and what the public record says about it. It is not clinical guidance and cannot inform device selection, implantation, or programming.

Referenced records
  • rel:t2-program
  • rel:t2-modulate
  • metric:t2-amplitude
  • metric:t2-frequency
  • metric:t2-contacts
  • metric:t2-service
  • lim:no-vendor-parameters
  • lim:symptom-modulation-not-repair
  • lim:not-clinical-guidance
Coverage limit

Programming values are clinician-set and device-specific; Corpus records the parameters that exist, not any value for them.

Chapter 4 · evidence

What the public record covers

The chain comes from device registration. The approval records show the marketed systems approved under motor-symptom categories, and a registration fact that matters to a reader: the generic intracerebral stimulator category a search finds first carries no approvals on file, which is a fact about how the classification database is organised, not evidence that no approved therapy exists. Post-market reports filed against the tremor category are attached as counts with no denominator.

Configuration focusImplanted pulse generator (schematic)Extension lead (schematic)Intracranial electrode (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Reports filed as malfunctionreports received
context dependent · 26869
Recall records on filerecall records
context dependent · 46
Device and regulatory evidence
  • device registration

    Component chain of a deep-brain stimulation system. A deep-brain stimulation system is registered as an implanted pulse generator placed in a chest pocket, an extension lead tunnelled under the skin, and an electrode passing through a cranial entry point to a deep brain target. Stimulation settings are changed from outside the body with a clinician programmer.

    This is component topology only. Corpus renders the chain schematically and carries no lead trajectory, contact spacing, or target coordinate for any system.

  • regulatory approval

    The marketed deep-brain stimulation systems are approved under motor-symptom categories. The systems marketed for parkinsonian tremor and for wider parkinsonian symptoms are class III devices carrying premarket approvals. The approval numbers on file for each category are attached to this record.

    An approval is granted for a stated indication in a stated population. It is not a general statement that stimulation works, and it does not extend to indications outside the application.

  • device registration

    The obvious category is not the approved one. The generic implanted intracerebral stimulator classification is the category a reader searching for deep-brain stimulation would find first, and it carries no premarket approvals on file. The marketed systems sit under the motor-symptom categories instead. Both are attached here so the empty category is visible rather than absent.

    An empty category is a fact about how the classification database is organised. It is not evidence that no approved therapy exists, which is exactly the wrong conclusion to draw from it.

  • adverse event report

    Post-market reports filed against the deep-brain stimulation category. Reports filed with the FDA against the implanted stimulator category approved for parkinsonian tremor are attached to this record, broken down by the event type the reporter selected.

    These are reports received across every manufacturer in the category over the life of the database. They are not events that occurred, not a rate, and not evidence that a device caused any outcome.

Declared limitations

MAUDE is passive surveillance. Report counts have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.

Corpus publishes no efficacy estimate, outcome score, or candidacy criterion for any configuration in this pack. Outcomes vary between individuals and are not derivable from the records cited here.

Referenced records
  • ev:t2-topology
  • ev:t2-approval
  • ev:t2-category-boundary
  • ev:t2-postmarket
  • metric:t2-malfunction-reports
  • metric:t2-recall-records
  • lim:passive-surveillance
  • lim:no-outcome-estimate
Coverage limit

No efficacy estimate or outcome score is published. Report counts are reports received across every manufacturer over the life of the database.

Chapter 5 · regulatory

How the categories reach the market

The systems marketed for parkinsonian tremor and for wider parkinsonian symptoms are class III devices carrying premarket approvals, as are the essential-tremor and dystonia categories on file. The obsessive-compulsive disorder indication reached the market through a humanitarian device exemption, which requires a demonstration of probable benefit rather than the demonstration of effectiveness an approval requires. The generic intracerebral stimulator category is listed with no premarket record.

Premarket approvals on fileapproved applications
context dependent · 2
Device and regulatory evidence
  • regulatory approval

    The marketed deep-brain stimulation systems are approved under motor-symptom categories. The systems marketed for parkinsonian tremor and for wider parkinsonian symptoms are class III devices carrying premarket approvals. The approval numbers on file for each category are attached to this record.

    An approval is granted for a stated indication in a stated population. It is not a general statement that stimulation works, and it does not extend to indications outside the application.

  • regulatory approval

    The obsessive-compulsive disorder indication came through a humanitarian exemption. Deep-brain stimulation for obsessive-compulsive disorder reached the market through a humanitarian device exemption, a route intended for small patient populations. Its record carries no premarket approval, and that distinction is attached here.

    A humanitarian device exemption requires a demonstration of probable benefit, not the demonstration of effectiveness a premarket approval requires. Treating the two as equivalent overstates what is known.

  • device registration

    The obvious category is not the approved one. The generic implanted intracerebral stimulator classification is the category a reader searching for deep-brain stimulation would find first, and it carries no premarket approvals on file. The marketed systems sit under the motor-symptom categories instead. Both are attached here so the empty category is visible rather than absent.

    An empty category is a fact about how the classification database is organised. It is not evidence that no approved therapy exists, which is exactly the wrong conclusion to draw from it.

Product codeClassMarket pathwayPremarket recordsRecallsReports
MHYStimulator, Electrical, Implanted, For Parkinsonian Tremor3Premarket approval2P140009, P9600094653,536
NHLStimulator, Electrical, Implanted, For Parkinsonian Symptoms3Premarket approval2P150031, P96000941,837
PJSStimulator, Electrical, Implanted, For Essential Tremor3Premarket approval1P15003102,296
SGSDeep Brain Stimulation For The Treatment Of Dystonia3Premarket approval1P96000900
OLMDeep Brain Stimulator For Obsessive Compulsive Disorder (Ocd)FHumanitarian device exemption00247
GYZStimulator, Intracerebral/Subcortical, Implanted3Premarket approval0073

A product code is a regulatory category, not a product; every count covers all devices in the category from every manufacturer. Premarket records are approvals plus clearances on file. Reports are MAUDE reports received, which are not events that occurred and carry no denominator. Retrieved from openFDA 2026-07-22.

Declared limitations

A humanitarian device exemption is a route to market for a small patient population. It is not a premarket approval and does not carry the same demonstration of effectiveness.

An FDA product code names a regulatory category, not a product. Every count attached to a code covers all devices cleared or approved in that category, from every manufacturer.

Coverage limit

An approval is granted for a stated indication in a stated population. It is not a general statement that stimulation works.