Educational reference only. Not a medical device. Not diagnostic medical advice. Always consult a qualified clinician.

← Transhuman · Powered lower-limb prosthesis · Reviewed device pathway

Powered lower-limb prosthesis: socket to step

Follow the device chain through where it meets the body, what can be adjusted, the public device and regulatory record, and the FDA product codes resolved for it. Product codes replace the trial shelf: every cited code is reconciled against the committed openFDA pack, and at least one carries a premarket record on file before this page can exist.

Reviewed September 3, 2026 · Re-review due September 3, 2027 · 3 product codes cited, 3 with premarket records

Chapter 1 · definition

Start with the control loop

A powered transfemoral prosthesis is a socket carrying load from the residual limb, a powered knee and a powered ankle joined by a pylon, a foot, load sensing, an onboard controller, and a battery. The open-source reference platform documents that architecture in the open. Corpus names the components and the relationships that sense, power, control, and replace function; it carries no commercial product's mass, geometry, or control law.

Configuration focusSocket (schematic)Load and position sensing (schematic)Gait controller (schematic)Prosthesis battery (schematic)Knee actuator (schematic)Powered knee unit (schematic)Ankle actuator (schematic)Powered ankle unit (schematic)Pylon (schematic)Prosthetic foot (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Device and regulatory evidence
  • device registration

    Component chain of a powered lower-limb prosthesis. A powered transfemoral prosthesis is built as a socket carrying load from the residual limb, a powered knee and a powered ankle joined by a pylon, a foot, load sensing, an onboard controller, and a battery. The open-source reference platform documents that architecture in the open.

    The open-source reference documents one research platform. Corpus renders the architecture schematically and carries no commercial product's mass, geometry, control law, or joint torque.

Referenced records

Chapter 2 · anatomy

Where the device meets the limb

The socket is the only interface with the body: it carries load from the residual limb through the skin, so the left femur and the skin are highlighted for the interface. Everything below the socket is device. The overlay is schematic and its anchor resolves to a whole atlas structure, so the rendered socket indicates the limb, not a fitted shape.

Configuration focusSocket (schematic)Residual limb interface (schematic)Left femur (atlas)Skin (atlas)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Load transfer surface
context dependent · fit specific
Declared limitations

The overlay is placed on reviewed attachment anchors that resolve to whole atlas structures. Anchor precision is region-level or orientation-only, so the rendered position indicates a body region, not a surgical location.

Device geometry in this overlay is Corpus-authored schematic form. It shows where a component sits and what it connects to, not the shape, size, or internal construction of any manufactured device.

Referenced records
  • rel:t3-interface
  • metric:t3-load-transfer
  • lim:anchor-precision
  • lim:corpus-schematic-geometry
Coverage limit

Load transfer is fit-specific. No socket geometry, liner, or suspension method is stored.

Chapter 3 · interventions

What the controller does with a step

Load sensors report to the controller at a platform-specific rate; the controller commands torque at the knee and ankle actuators, drawing on the battery, whose runtime depends on activity. Those are the adjustable quantities in this loop and Corpus records them as metrics with no value: gains, torque limits, and gait parameters belong to the platform and the fitting.

Configuration focusLoad and position sensing (schematic)Gait controller (schematic)Knee actuator (schematic)Ankle actuator (schematic)Prosthesis battery (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Sensor sampling rateHz
context dependent · platform specific
Commanded joint torqueN m
context dependent · platform and gait specific
Runtime between chargeshours
context dependent · activity dependent
Declared limitations

No vendor stimulation parameters, control gains, programming values, or fitting procedures are published here. Those are device-specific and clinician-set.

This pack orients a reader to how a configuration is put together and what the public record says about it. It is not clinical guidance and cannot inform device selection, implantation, or programming.

Referenced records
  • rel:t3-sense
  • rel:t3-control
  • rel:t3-power
  • metric:t3-sensor-rate
  • metric:t3-joint-torque
  • metric:t3-runtime
  • lim:no-vendor-parameters
  • lim:not-clinical-guidance
Coverage limit

No control gain, torque limit, or runtime figure is published for any product.

Chapter 4 · evidence

What the public record covers

The architecture comes from the open-source reference platform and device registration. The regulatory record shows the external knee and ankle-foot categories as class I devices held to general controls, a materially lighter route than the class III implants in the other two configurations. Post-market reports and recall records against those categories are attached as counts with no denominator.

Configuration focusPowered knee unit (schematic)Powered ankle unit (schematic)Socket (schematic)

Device components are Corpus-authored schematic form placed on reviewed anchors; atlas structures are the human base model.

Reports filed as malfunctionreports received
context dependent · 227
Recall records on filerecall records
context dependent · 17
Device and regulatory evidence
  • device registration

    Component chain of a powered lower-limb prosthesis. A powered transfemoral prosthesis is built as a socket carrying load from the residual limb, a powered knee and a powered ankle joined by a pylon, a foot, load sensing, an onboard controller, and a battery. The open-source reference platform documents that architecture in the open.

    The open-source reference documents one research platform. Corpus renders the architecture schematically and carries no commercial product's mass, geometry, control law, or joint torque.

  • regulatory approval

    External limb components are regulated as class I general-controls devices. External knee and ankle-foot limb components are class I devices held to general controls, a materially lighter regulatory route than the class III implants in the other two configurations. The classification records are attached here.

    A light regulatory route reflects how the category is classified, not how well any product performs. It also means there is no premarket approval record to read for these components.

  • adverse event report

    Post-market reports filed against external limb components. Reports filed with the FDA against the external knee and ankle-foot component categories are attached to this record, broken down by the event type the reporter selected, together with the recall records on file.

    These are reports received across every manufacturer in the categories over the life of the database. They are not events that occurred, not a rate, and not evidence that a device caused any outcome.

Declared limitations

MAUDE is passive surveillance. Report counts have no denominator, are subject to under- and over-reporting, and cannot establish incidence, prevalence, or that a device caused the outcome described.

Corpus publishes no efficacy estimate, outcome score, or candidacy criterion for any configuration in this pack. Outcomes vary between individuals and are not derivable from the records cited here.

Referenced records
  • ev:t3-topology
  • ev:t3-classification
  • ev:t3-postmarket
  • metric:t3-malfunction-reports
  • metric:t3-recall-records
  • lim:passive-surveillance
  • lim:no-outcome-estimate
Coverage limit

A light regulatory route reflects how the category is classified, not how well any product performs. No outcome estimate is published.

Chapter 5 · regulatory

How the categories reach the market

The external knee and ankle-foot component categories are class I general-controls devices. They carry no premarket approval record to read; the clearances on file for each category are attached. The powered external-limb overload warning device is a separate category that reaches the market by premarket notification, and its clearance numbers are attached. Every count covers the whole category from every manufacturer.

Regulatory classFDA device class
context dependent · 1
Device and regulatory evidence
  • regulatory approval

    External limb components are regulated as class I general-controls devices. External knee and ankle-foot limb components are class I devices held to general controls, a materially lighter regulatory route than the class III implants in the other two configurations. The classification records are attached here.

    A light regulatory route reflects how the category is classified, not how well any product performs. It also means there is no premarket approval record to read for these components.

Product codeClassMarket pathwayPremarket recordsRecallsReports
ISYJoint, Knee, External Limb Component1Class I, general controls1K10185917499
ISHComponent, External, Limb, Ankle/Foot1Class I, general controls4K051256, K791331, K820505, K8233961395
IRNDevice, Warning, Overload, External Limb, Powered2Premarket notification (510(k))11K023161, K060150, K770405, K792241, K882974, K931517, K950656, K955034, K960307, K962591, K99131300

A product code is a regulatory category, not a product; every count covers all devices in the category from every manufacturer. Premarket records are approvals plus clearances on file. Reports are MAUDE reports received, which are not events that occurred and carry no denominator. Retrieved from openFDA 2026-07-22.

Declared limitations

An FDA product code names a regulatory category, not a product. Every count attached to a code covers all devices cleared or approved in that category, from every manufacturer.

Coverage limit

A clearance establishes substantial equivalence to a predicate, not effectiveness.